华为UPS机房专用华为UPS机房专用 华为UPS是一种含有储能装置,以逆变器为主要组成部分的恒压恒频的不间断电源,主要用于给单台计算机、计算机网络系统或其它电力电子设备提供不间断的电力供应。 UPS电源是一种含有储能装置,以逆变器为主要组成部分的恒压恒频的不间断电源,主要用于给单台计算机、计算机网络系统或其它电力电子设备提供不间断的电力供应。 HUAWEI UPS room dedicated Huawei UPS is a constant voltage and constant frequency uninterrupted power supply with energy storage device and inverter as its main component. It is mainly used to provide uninterrupted power supply to a single computer, computer network system or other power electronic equipment. UPS power supply is a kind of uninterrupted power supply with energy storage device and constant voltage and frequency, which is mainly composed of inverter. It is mainly used to provide uninterrupted power supply for a single computer, computer network system or other power electronic equipment. Working principle UPS is used as a voltage regulator when the power input is normal; UPS provides continuous and stable 220V alternating current through inverter conversion when the power supply is interrupted (power failure) to maintain the normal operation of computers, computer networks or other power equipment for a period of time. application UPS has been widely used in aerospace, industry, communications, national defense, hospitals, computer networks, transportation and other fields, is an important power supply equipment for enterprises. How can such an important UPS improve its work quality and extend its power supply life? First of all, let's learn about the service life of UPS ups. The life of UPS depends on the environment of operation, maintenance and maintenance. Normally, UPS power can last 8-10 years, while properly maintained UPS power can last more than 15 years, like data centers in many parts of the United States, where the UPS power has never been replaced. However, in practice, the life of UPS is usually only about 5 years. So how can we effectively maintain and extend the life of UPS power? Maintenance of UPS (1) perfect maintenance conditions (ideal state) UPS room should be air-conditioned and anti-static floor room, lightning protection effect is better, to dust, moisture, sunscreen. The input voltage is within the design range, and the most reasonable range of load is 30%-60%. Maintain at least once a year. In reality, it is difficult for us to do this, so as far as possible to master some common sense of maintenance. For example, to prevent dust accumulation in the chassis, regular maintenance of batteries in the power supply. (2) keep the appropriate ambient temperature. The best ambient temperature is between 20-25 degrees. According to the test, once the temperature exceeds 25 degrees, the life of the battery will be reduced by half by 10 degrees. In addition, the increase of ambient temperature will lead to the enhancement of chemical activity in the battery, resulting in a large amount of heat energy, which in turn will cause the ambient temperature to rise and enter a vicious cycle. (3) regular charge discharge Previously we learned that UPS works by storing energy - inverting - providing alternating current, and we can think of it as a battery whose life can be reduced by long-term floating charge or discharge. Therefore, it is better to discharge completely every 2-3 months, after discharge, and then charge more than 8 hours according to the regulations. (4) using communication function The intelligent communication function can greatly facilitate the use and management of UPS power and its batteries. Most large and medium UPS have the functions of communication and program control with computers. By installing the corresponding software, we can query UPS related information, parameters, setting timing, automatic shutdown and alarm on the microcomputer. (5) replace the waste / broken battery in time. Large and medium-sized UPS power supply is equipped with batteries ranging from 3 to 80, so when individual batteries are damaged, it will affect the overall UPS DC power supply. Maintenance personnel should check each battery, replace new batteries, prohibit the combination of different amperes, different brands of batteries. Prolong UPS life (1) use of AC voltage stabilizer After using the UPS power supply, there is no need to add AC voltage stabilizer. If it must be added, it should be placed in the front of the UPS power supply, that is, the city power first through the AC regulator, then through the UPS power supply, and then to the load. (2) avoid overload using UPS power supply. When using UPS power supply to calculate the size of the load, to avoid overload or too small, reasonable load should be controlled between 50% to 80%. (3) try not to overload. In general, the load of on-line UPS power supply should be controlled at 70% - 80%, while the load of backup UPS power supply should be controlled at 60% - 70%. Note that excessive light load is not good, though not as serious as overload. (4) do not use diesel generators. The UPS power supply should not be supplied by the diesel generator, because its frequency is often unstable, affecting the normal operation of the UPS power supply. (5) boot and shutdown sequence when using UPS power supply. The correct turn-on sequence should be to turn on the UPS power supply to power it first, and then turn on the various loads, so as to avoid the damage caused by the instantaneous current impact on the UPS startup; turn off the order is just the opposite. (6) UPS power first charging skills The newly purchased UPS power source should be inserted into the 220V power grid at least for more than 12 hours to ensure full charging. (7) UPS power can not be idle for a long time. Excessive discharge and long-term open circuit idle of the battery will increase the internal resistance of the battery and deteriorate its charge and discharge performance. If the UPS power supply is not used for a long time, it should be turned on 24 hours every 2-3 months, and keep the UPS power supply in the inverting state for 2-3 minutes. 华为UPS机房专用 |