华为UPS并机故障解决方案华为UPS并机故障解决方案 近年来,中国电信大力开发和推广信息化应用,以全新的多业务、多网络、多终端融合及价值链为延伸,改造建设地方工程项目,使信息化成果更好地惠及社会各行业和广大人民群众。多年来,作为中国电信可靠的合作伙伴,科华恒盛积极帮助客户转型升级和信息化推广建设,携自主研发的高端电源和数据中心产品方案,在中国电信各地工程项目建设中广泛应用,为客户的基站、机房、云计算IDC建设等,提供可靠、安全、智慧的绿色电能,以及建设、运营、租赁等云基础服务保障。作为通信领域领先的设备电力保护提供商,科华恒盛28年来始终致力于电力电子技术的自主创新和发展应用,积极参与通信领域的信息化安全建设和国产化的设备替代,助力通信企业为国民经济发展和社会信息化建设作出更大贡献。
华为UPS并机故障解决方案 HUAWEI UPS parallel machine failure solution In recent years, China Telecom has vigorously developed and popularized the application of information technology, transforming and constructing local engineering projects with the brand-new multi-service, multi-network, multi-terminal integration and value chain as the extension, so as to better benefit all sectors of society and the broad masses of the people. Over the years, as a reliable partner of China Telecom, Kehua Hengsheng has actively helped customers upgrade and promote information technology. With its own research and development of high-end power supply and data center products, Kehua Hengsheng has been widely used in China Telecom project construction all over the country. Provide reliable, safe, intelligent green power, as well as construction, operation, leasing and other cloud infrastructure services. As a leading equipment and power protection provider in the field of communications, Kehua Hengsheng has been committed to independent innovation and development and application of power electronics technology for 28 years. Kehua Hengsheng has actively participated in information security construction in the field of communications and equipment substitution of localization, and helped communication enterprises to make greater contributions to national economic development and social information construction. Offer. Failure phenomenon Power maintenance personnel in the patrol inspection found a UPS1 + 1 parallel system abnormal switch to bypass power supply, at the same time, UPS1-2 alarm, display inverter fault. After the failure, the maintenance personnel contacted the engineer of a company urgently. According to the suggestion of the manufacturer engineer, the UPS1-1 inverter was restored, the load was switched back from bypass to UPS1-1 inverter with load, and then the UPS1-2 power-down was restored to work properly. After operation, the UPS1-1 inverter can be turned on normally. The load has been switched from bypass to UPS1-1 inverter with load. After the power of UPS1-2 is down, the restart still shows "inverter fault alarm". Most of the power frequency UPS power supply inverter equipment in the market adopts IGBT technology, built-in isolation transformer, switching frequency in 1K~3KHZ, and the frequency of the market power in 50HZ, switching frequency is 20~60 times of the market power frequency, such a low switching frequency will produce a large number of low-order harmonics, power frequency machine because of low switching frequency, can not filter out the low-order harmonics. Harmonics, and 3 * n harmonics can not enter the triangular input transformer, so the isolation transformer on the power frequency machine voltage plays a great role, good voltage, to ensure the use of requirements. Isolation transformer plays an indispensable role in the configuration of early UPS power supply. With the development of technology, the number of inverter isolation transformers in UPS is becoming less and less. Now there is only one isolation transformer in power frequency machine. Because of the structure characteristics of the fuselage itself, it can not be eliminated. Huawei UPS power supply has been rejected by virtue of advanced technology. In addition to isolation transformer, high-frequency non-isolation transformer Huawei UPS power supply, reduce the volume and weight to improve efficiency, is bound to bring a new round of technological innovation, thus purifying the UPS uninterruptible power market, the elimination of power frequency UPS power supply. Processing steps 1. The inverters of UPS 1-2 are red, and the fault alarm shows "inverter fault". The internal circuit breaker of UPS is in situ, and the inverters of UPS 1-1 supply power normally. The machine status and fault information of UPS1-2 are inspected by the dispatching software, and the equipment REPORT is deduced to confirm that there are no other abnormal alarms and start power off for maintenance. After replacing three output AC capacitors on site, engineers measured the old capacitors removed and found that the capacity of one of the AC capacitors decreased directly from the nominal 600UF to 0, and the capacitors were completely invalid. 2. When the output capacitor is replaced, an engineer disconnects the output switch of UPS1-2 and tests it by a single machine in manual mode. The output voltage of UPS1-2 is adjusted step by step, and the filter current of the output voltage and the AC capacitor is measured. All the indexes are normal. After the UPS1-2 is removed from the manual mode, the single machine runs normally. 3. After the maintenance of the various functional tests, we will UPS1-2 circuit breakers to restore the state and turn on the UPS1-2 inverter, but the UPS1-2 inverter lamp has been flickering, can not carry out parallel machine, test many times, occasionally successful parallel machine, but after closing the inverter button again can not parallel machine, it seems that UPS1-2 has no other failures Completely restored. 4. After analyzing the working principle and related circuits of this UPS, we suspect that the "switch circuit control board AROI" is abnormal, so we use the warehouse to remove the board for maintenance and replacement. After replacing the board, we need to rewrite the parameters and check the board. After completing the relevant operation and testing, the UPS runs normally and the UPS failures are completed. Repair. Fault summary 1. It is suggested to replace the vulnerable parts of UPS equipment which has been running for more than 5 years to prevent the recurrence of similar faults. The vulnerable parts include AC filter capacitor, DC bus filter capacitor, fan, auxiliary power supply board and so on, so as to improve the reliability of equipment operation and prolong the service life of UPS. 2, for overdue use of UPS should be replaced in time, this set of UPS has reached the life expectancy time. Therefore, it is planned to carry out the cutting replacement this year, and the acceptance of the new UPS and the arrival of the cutting cable have been completed. 3. It is suggested that UPS products should be maintained in the original factory to ensure the depth of UPS equipment maintenance. At the same time, similar equipment hidden dangers can be prevented and eliminated in advance, fault responsiveness can be improved, and the time limit for fault site treatment can be accelerated. HUAWEI UPS parallel machine failure solution华为通信电源,华为电源官网,华为高频开关电源,华为-48v开关电源,华为开关电源模块,华为网络机柜,华为服务器机柜,华为室外一体化机柜,华为OLT电源,华为直流电源,华为开关电源,华为综合柜,华为UPS,UPS5000-E,UPS2000-A,UPS2000-G,UPS8000-D,UPS5000-A,华为TP48200,华为TP48300,华为TP48600 |