华为UPS电源由哪些部分组成?华为UPS电源由哪些部分组成? 电力UPS电源与电力直流操作电源系统一起,组成发电厂,变电站的专用不间断电源,向微机、通讯、载波、事故照明及其它不能停电的设备供电。 电力UPS电源与电力直流操作电源系统一起,组成发电厂,变电站的专用不间断电源,向微机、通讯、载波、事故照明及其它不能停电的设备供电。从电厂或变电站现有直流操作电源取电,不必像常规UPS那样需要单设蓄电池组,从而避免蓄电池的重复投资,减少系统维护,减低运行成本。 What parts of HUAWEI UPS power supply consist of? The power UPS power supply, together with the power DC operating power supply system, forms a special uninterrupted power supply for power plants and substations, which supplies power to microcomputers, communications, carriers, accident lighting and other equipment that can not be cut off. The power UPS power supply, together with the power DC operating power supply system, forms a special uninterrupted power supply for power plants and substations, which supplies power to microcomputers, communications, carriers, accident lighting and other equipment that can not be cut off. It is not necessary to install single battery pack as conventional UPS to take power from existing DC operating power supply of power plant or substation, so as to avoid repeated investment of battery, reduce system maintenance and operation cost. The working principle and output characteristics of power UPS are exactly the same as those of traditional UPS. However, since it is connected to DC operating power supply system, its DC input characteristics must meet the special requirements of power system. Power UPS is designed for power plant, substation and other power industry. In power plant and power system, DCS (Distributed Control System), monitoring system, automation instrument, dispatching communication system, microcomputer system and other core equipment require very high quality and reliability of power supply, and special UPS power supply is needed. These loads are extremely large. Most are single-phase loads. Power UPS system is generally composed of three parts: power UPS mainframe, bypass voltage regulator, output feeder cabinet and so on. 1. Power UPS main cabinet: input-output isolation transformer, rectifier, inverter, static bypass switch, bypass switch, reverse diode; 2, bypass isolation regulator: bypass isolation transformer, bypass regulator, manual / bypass maintenance switch; 3, feeder cabinet: loop distribution unit, monitoring instrument, control switch and signal indication; The power UPS special power supply adopts 1+1 redundant power supply system. Aiming at the application load and environment of power system, the industrial-grade AC protection power supply manufactured by advanced technology can fully meet the demand of power supply reliability for power DCS system and other loads. The power UPS mainly consists of the following systems: two level transformation. The first stage transformation uses a rectifier (AC-DC). The alternating current after the input transformer is changed into a stable DC current. The second stage converter (DC-AC) uses an inverter to convert the rectified DC output into a sinusoidal AC output through isolation to the load. Isolation part: The input isolation transformer isolates the AC input and DC to protect the DC side equipment; the output isolation transformer isolates the AC and DC input from the AC output to protect the load side equipment. Dual isolation ensures the real complete electrical isolation of the three ports of DC input, AC input and AC output. Rectifier part: converting the input AC power into a stable DC and sending it into the inverter equipment. Inverter part: the external DC or rectified DC power supply into a stable sine wave AC power supply. Control part: Control the inverter power supply to follow the benchmark power supply, and keep the same phase and frequency with it, automatically adjust, and make the power supply in the prescribed range, according to the set protection value operation or protection. Display part: using LCD and LED status simulation disk to accurately reflect the running status and fault information of the equipment. Switching part: Adopting relay or static electronic switch, the power supply of bypass, power supply and inverter can be switched automatically. 华为通信电源,华为电源官网,华为高频开关电源,华为-48v开关电源,华为开关电源模块,华为网络机柜,华为服务器机柜,华为室外一体化机柜,华为OLT电源,华为直流电源,华为开关电源,华为综合柜,华为UPS,UPS5000-E,UPS2000-A,UPS2000-G,UPS8000-D,UPS5000-A,华为TP48200,华为TP48300,华为TP48600 华为UPS电源由哪些部分组成? |